Testing Services |
Home : Testing Services |
Vibration Testing |
| | 
| | Electro Dynamic Vibration System |
Contact us today for your vibration testing needs or call toll-free 800-969-4050.
Types of vibration testing at DATASYST include:
Random Vibration - replicates complex frequencies in a chosen bandwidth. Vibration environments may have input from multiple sources such as wheels over a road. In these vibration exposures it may be more accurate to analyze and test using random vibration.
In random vibration the primary concern is the spectral content of the vibration being generated. Most random vibration tests are conducted using Gaussian random suppositions where maximum amplitude is not definable, and levels are measured in RMS values.
Sine Sweep Vibration - are sweeps across a frequency spectra, at a specific rate, testing can be performed to identify resonant frequencies of a UUT.
With sinusoidal vibration, the relationship between acceleration, velocity and displacement is fixed and frequency dependent. Variation in any one of these three parameters affects another, for this reason, all should be considered simultaneously when specifying sine vibration.
Sine Dwell Vibration - are dwells at a specific frequency, often at a resonant frequency, to duplicate a worst case condition for the UUT.
With sinusoidal vibration, the relationship between acceleration, velocity and displacement is fixed and frequency dependent. Variation in any one of these three parameters affects another, and for this reason, all of them should be considered simultaneously when specifying or observing sine vibration.
Sine on Random Vibration - is performed by overlaying a sine dwell on a random vibration profile.
Combined Environment Vibration - allows exposure of a UUT to vibration and an environmental conditions (hot/cold) simultaneously.
See an article on The Importance of Fixture Design (Fixturing Article)
Contact DATASYST today to discuss your test program needs: 800-969-4050.
|
Capabilities / Equipment: |
| | Electro-Dynamic Vibration Systems (eight Available)
- Ling, Unholtz-Dickey and LDS
- Force ratings to 23,000 force pounds
- Frequency range of DC to 14,000 Hz
- Three inch stroke with tables to five foot by five foot
Servo-Hydraulic Vibration Systems
- MTS, Excite
- Force ratings to 30,000 force pounds
- Frequency range of DC to 1000 Hz
- Strokes to 10" with tables to six foot by five foot
|
Frequently Used Specifications: |
| | -
MIL STD 202, Method 201A; Vibration
MIL STD 202, Method 204D; High Frequency Vibration
MIL STD 202, Method 214A; Random Vibration
A2LA Accredited
-
MIL STD 810; Method 514; Vibration
MIL STD 810; Method 516; Mechanical Shock
MIL STD 810; Method 519; Gunfire Vibration
A2LA Accredited
-
MIL STD 883; Method 2002; Mechanical Shock
MIL STD 883; Method 2005; Vibration Fatigue
MIL STD 883; Method 2007; Variable Frequency Vibration
A2LA Accredited
-
IEC 68-2-29; Bump (shock)
-
GR-63-CORE, Section 4.3.1; Packaged Equipment Shock
GR-63-CORE, Section 4.3.2; Unpackaged Equipment Shock
GR-63-CORE, Section 4.4.1; Earthquake Environment (vibration)
GR-63-CORE, Section 4.4.4; Office Vibration
GR-63-CORE, Section 4.4.5; Transportation VIbration
A2LA Accredited
-
Various SAE Mechanical Shock/Mechanical Vibration
SAE J1211; Section 4.7, Mechanical Vibration
SAE J1211; Section 4.8, Mechanical Shock
SAE J1455; Section 4.9, Mechanical Vibration
SAE J1455; Section 4.10, Mechanical Shock
A2LA Accredited
-
Various Bellcore and ASTM.
DATASYST performs vibration testing in 25,000 square feet of laboratory space located outside of Milwaukee, Wisconsin ((WI) and within driving distance for our clients in Chicago, Illinois (IL), Indiana (IN), Ohio (OH) and Michigan (MI).
Contact us today or call Toll Free 800-969-4050 to discuss your testing. We look forward to working with you on your next test program.
|
DATASYST Engineering & Testing Services, Inc. performs vibration testing, shock testing, strain and stress testing, load and fatigue testing, environmental testing, engineering analysis and NEBS testing in 25,000 square feet of laboratory space located outside of Milwaukee, Wisconsin and within driving distance for our clients in the Chicago, Illinois area. We look forward to working with you on your next test program.
|
|